DIN-LVD-12_Web

DIN-LVD-24

DIN Mount Low Voltage Disconnects, 50 Amps

Category:

Product Description

The DIN-LVD-24 is pre-set to disconnect the load at 20 VDC. However, to prevent premature or false disconnect when the battery voltage drops below the 20 volt threshold a 2 minute timer is started. If the battery recovers to above 20 volts, the timer resets and waits. The battery can and will recover if the system is a repeater or remote base station or similar equipment that has a varying demand that fluctuates from low to high current. The 2-minute delay ensures the battery is not disconnected until necessary to prevent damage.

After the AC main power is restored and the battery is recharging, the DIN-LVD-24 will reconnect the load when the battery voltage exceeds 25.0 volts.

Product Specifications

Input Range VDC:
0-35
Disconnect / Reconnect VDC:
20 / 25
Amps (Max):
50
Weight (lbs):
1.75
Dimensions:
2.75"H x 8"W x 4"D