DIN-LVD-12_Web

DIN-LVD-12

DIN Mount Low Voltage Disconnects, 75 Amps

Category:

Product Description

The DIN-LVD-12 is pre-set to disconnect the load at 10.4 VDC. However, to prevent premature or false disconnect when the battery voltage drops below the 10.4 volt threshold a 2-minute timer is started. If the battery recovers to above 10.4 volts, the timer resets and waits. The battery can and will recover if the system is a repeater or remote base station or similar equipment that has a varying demand that fluctuates from low to high current. The 2-minute delay ensures the battery is not disconnected until necessary to prevent damage.

After the AC main power is restored and the battery is recharging, the DIN-LVD-12 will reconnect the load when the battery voltage exceeds 12.5 volts.

Product Specifications

Input Range VDC:
0-15
Disconnect / Reconnect VDC:
10.4 / 12.5
Amps (Max):
75
Weight (lbs):
1.75
Dimensions:
2.75"H x 8"W x 4"D

Downloadable PDFs

© DuraComm Power Supplies, A Mission Critical Electronics Brand. All rights reserved. | 4420 NE Chouteau Tfwy, Ste 204 • Kansas City, MO 64117
MCE Home American Battery Charging Home Asea Marine Home Duracomm Home Kussmaul Home Newmar DC Power Home Power Products Home Purkey Power Products Home Xantrex Products Home ZeroRPM Home
Site managed by Mission Critical Electronics
Terms & Conditions  |  Privacy Policy  |  Careers  |  Partners Login